Electric Water Heater Magnesium Anode Rod Solar Vacuum Tube Magnesium Anode Rod Water Heater Tank Accessories for Descaling Decontamination Protection

Electric Water Heater Magnesium Anode Rod Solar Vacuum Tube Magnesium Anode Rod Water Heater Tank Accessories for Descaling Decontamination Protection

Don't pay
$37.99 Save 26%
$27.99
/
  • AU Stock - Leaves warehouse in 1-2 business days
  • FAST Shipping -
    Shipping info


    Shipping Guide

    • VIC 3 - 5 working days
    • NSW, SA, ACT 4 - 8 working days
    • QLD, NT, WA, TAS 7 - 10 working days

    PO Box not accepted Learn more

    • Secure live courier tracking
    • Free freight protection
    • 12-month warranty
  • In stock, ready to ship
  • Inventory on the way
Shipping calculated at checkout.

  • from $10/wk
  • from $6.99
    Pay in 4 interest-free payments of $6.99
V1294-YM0626-3113220312511

1、Magnesium Rod Theoretical Root: The theoretical root of magnesium rod is the principle of cathodic protection. Cathodic protection is an electrochemical terminology, which is to supplement a large number of electrons to the metal to be protected, so that the whole protected metal is in a state of electron surplus, so that all points on the metal surface reach the same negative potential, and metal atoms are not easy to lose electrons and become ions dissolved in solution. There are two ways to realize cathodic protection of metals, impressed current cathodic protection and sacrificial anode cathodic protection.
2、Forced impressed current protection method: Impressed current cathodic protection is to force the current to flow from the soil to the protected metal through the impressed DC power supply and auxiliary anode, so that the potential of the protected metal structure is lower than the surrounding environment. In the electrolytic cell formed by the protected metal and auxiliary anode in the corrosive medium, they are respectively the negative electrode and the positive electrode. The auxiliary anode itself does not consume, but only serves as an intermediary to provide current to the protected metal continuously, so that only reduction reaction occurs on the protected metal surface, thus preventing corrosion. The forced impressed current protection method requires a continuous current, so a potentiostat must be used in this protection scheme to control the current. For this reason, this protection method is generally used in large metal structure equipment, such as the protection of dozens of kilometers long oil pipeline in airport oil depot.
3、Sacrificial Anode Protection Method: Sacrificial anode cathodic protection is to connect the metal with more negative potential or more active potential with the protected metal, and to be in the same electrolyte, so that the electrons on the metal can be transferred to the protected metal, so that the whole protected metal is in a negative and the same potential. That is to say, the primary battery is formed by the two, and the protected metal is oxidized instead of the protected metal, which is consumed by corrosion instead of the protected metal. In short, the sacrificial anode protection method is to find a shield for the metal to be protected, and let this shield complete all the corrosion. After it is sacrificed, we will find a new shield to continue to block the arrow. In a word, it is the lost horse marshal. However, our "horse" was lost on purpose, not under compulsion. This is the principle of magnesium rod protection. The magnesium rod acts as a shield for the tank of the water heater, replacing the corrosion of the tank, thus ensuring the safety of the tank.
4、Product Material: Electric water heater magnesium anode rod is made of plastic and magnesium alloy material, fine workmanship makes the products durable, not easy to damage, and greatly extend the service life.
5、Closely Fitting: Water heater magnesium anode rod closely fits the original machine hole position with accurate shape and size design.
Item Type: Electric Water Heater Magnesium Anode Rod
Material: Plastic, Magnesium Alloy
Color: As Pictures Shown
Weight: Approx. 300g / 10.6oz
Magnesium Rod Specification: 58 vacuum tube magnesium rod, which can be directly inserted into 58 vacuum tube
1 x Electric Water Heater Magnesium Anode Rod
Products received faulty, damaged, or not as described are eligible for a return, refund, or replacement in accordance with local consumer laws. We are committed to ensuring all products meet the standards of quality and reliability expected by our customers. Please note that we do not accept returns or provide refunds for change of mind. We encourage you to carefully consider your purchase to ensure it meets your needs and expectations.

Related Collections:
Heat Protection, New Arrivals

Estimated delivery time frames:

- VIC 3 - 5 business days

- NSW, SA, ACT 4 - 8 business days

- QLD, NT, WA and TAS 7 - 10 business days 

All orders are dispatched within 24-48 hours from our Melbourne and Sydney distribution centres.

PO Box’s not accepted. Learn more

Secure shipping includes:

- Secure live courier tracking

- Free freight protection

- 12-month warranty

Payday Deals generally offers a 12-month warranty on all products, unless stated otherwise. Some products will be provided with extended warranty for your peace of mind.

Click here to view our change of mind returns policy.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

More from Heat Protection
Recently viewed